RTD Elements
Resistance Temperature Detectors (RTDs) - Platinum - Elements and Mounts
Part Numbering System
After locating a figure and part number in the below tables, you can fine tune the sensor for your application. If you require an American curve sensor and not the European curve, change the “E” to an “A” in the part number. For 500 Ω and not the standard 100 Ω sensor, change the “11” in the part number to “51”. 1000 Ω sensors can be ordered by changing the “11” to an “101”. Substitute any “X” and “Y” characters with your length requirements. RTDs are provided in four wire configurations as standard. This is the most accurate configuration.
Note: If you are using a transmitter you may be only able to use a three wire sensor. This can be designated by changing the “4” in the part number to a “3”. Two wire RTDs can be specified by changing the “4” with a “2” in the part number.
Construction
The standard metal sheath for RTD elements are 1/4” diameter made of 316 stainless steel. Inconel 600 sheaths can be specified by changing the “16” in the part number to a “09”.
Example part number: 4E164-11-24-12 four wire, European curve, 316 Stainless Steel 1/4 inch diameter sheath, 100 Ω , 24” probe and leads overall, 12” probe.
Note: Richards standard RTDs have a maximum service temperature rating of 400°C (752°F). Our high temperature RTDs have a maximum service temperature rating of 650°C (1202°F). If you would like to specify this option, add a “H” after the curve designation letter (A or E) in the catalog number.
Need to order a Dual element or Assembly? - Insert “D” after the “E” in the catalog number.
Example: 4ED164-1-24-12
RTD Element Configurations
√ 316SS 1/4” Dia. European Curve Element
√ 100Ώ Resistance
√ Four Wire Lead Configuration
√ Max. Temp. 400°C (752°F) or High Temp. Option 650°C (1202°F)
√ ± 0.04% resistance or ±0.1°C Accuracy
√ Need to Customize Your Assembly - Fine Tune the Part Number:
X = Overall Length Y = Probe or insertion Length
H = Hot Leg Length C = Cold Leg Length
Part Numbering System
After locating a figure and part number, you can fine tune the sensor for your application. If you require an American curve sensor and not the European curve, change the “E” to an “A” in the part number. If you require a 500 Ω and not the standard 100 Ώ sensor, change the “11” in the part number to “51”. 1000 Ώ sensors can be ordered by changing the “11” to a “101”. Substitute any “X” and “Y” characters with your length requirements. RTDs are provided in four wire configurations as standard. This is the most accurate configuration. Note: if you are using a transmitter you may be only able to use a three wire sensor. This can be designated by changing the “4” in the part number to a “3”. Two wire RTDs can be specified by changing the “4” with a “2” in the part number.
RTD Construction
The standard metal sheath for RTD elements is 1/4” diameter made of 316 stainless steel. Inconel 600 sheaths can be specified by changing the “16” in the part number to a “09”. Example part number: 4E164-11-24-12 is a four wire, European curve, 316 Stainless Steel 1/4 inch diameter sheath, 100 Ώ, 24” probe and leads overall, 12” probe.
Note: Richards standard RTDs have a maximum service temperature rating of 400°C (752°F). Our high temperature RTDs have a maximum service temperature rating of 650°C (1202°F). If you would like to specify this option, add an “H” after the curve designation letter (A or E) in the catalog number. Example Part Number: 4EH164-11-24-12 is a High Temperature, Four wire, European curve, 316 Stainless Steel 1/4 inch diameter sheath, 100 Ώ, 24” probe and leads overall, 12” probe.
Need to order a Dual element or Assembly? - Insert “D” after the “E” in the catalog number. Example: 4ED164-1-24-12
Note: Other configurations are also available which may not be shown.
Specifications
- 316SS 1/4” Diameter Sheath
- European Curve Element
- 100 Ω Resistance
- Four Wire Lead Configuration
- Max Temp. 400°C (752°F)
- High Temp. Option 650°C (1202°F)
- ± 0.04% resistance or ±0.1°C Accuracy
ACCESSORIES AND RELATED PRODUCTS
- RTD Elements + Mounts
- RTDs Assemblies + Thermowells